Naslov (srp)

Značaj korelacije analize gustine kosti i primarne stabilnosti kod izbora dizajna dentalnih implantata

Autor

Mikić, Mirko, 1987-, 65029129

Doprinosi

Vlahović, Zoran, 1971-, 58711305
Bubalo, Marija, 1973-, 1646951
Lazić, Zoran, 1963-, 5197415
Vasović, Miroslav, 1982-, 24921191

Opis (srp)

UVOD: Oseointegracija predstavlja preduslov uspjeha implantatne terapije. Kvalitet i kvantitet kosti, dizajn implantata i hirurška tehnika ugradnje, su najznačajniji faktori koji utiču na primarnu stabilnost implantata koja predstavlja preduslov oseointegracije. METODOLOGIJA: U razrešenju postavljenih ciljeva sprovedena je eksperimentalna studija na materijalu životinjskog porijekla: goveđem femuru i svinjskim rebrima i klinička prospektivna eksperimantalna studija na ljudima, sa nedostatkom jednog zuba u bočnoj regiji indikovanih za ugradnju implantata. U ovoj studiji su korišćene dvije vrste imlantata: samourezujući (Bredent-Narrow SKY) i neurezujući (Nobel Replace – Conical Connection) istih dimenzija. REZULTATI: Rezultati eksperimentalne studije su pokazali statistički značajnu povezanost gustine kosti izražene u HU jedinicama i primarne stabilnosti samourezujućih i neurezujućih dentalnih implantata izražene u ISQ jedinicama u kostima goveđeg femura i samourezujućih implantata i kostima svinjskog rebra. Nije bilo statistički značajne povezanosti neurezujućih dentalnih implantata u kostima svinjskog rebra. Samourezujući i neurezujući implantati nijesu pokazali statistički značajnost u primarnoj stabilnosti u kostima različitog kvaliteta. U kliničkoj studiji je dokazano da postoji statistički značajna jaka pozitivna povezanost između gustine kosti izražene u HU jedinicama izmjerene u softveru CBCT aparata i primarne stabilnosti dentalnih implantata izraženih u ISQ jedinicama; ZAKLjUČAK: Analizom gustine koštanog tkiva CBCT sniimka u softveru aparata izraženom u HU jedinicama može se predvidjeti stepen primarne stabilnosti samourezujućih i neurezujućih dentalnih implantata u kostima gustine D1, D2 i samourezujućih dentalnih imlantata u kostima slabijeg kvaliteta gustine D4. Stepen primarne stabilnosti neurezujućih dentalnih implantata u kostima slabijeg kvaliteta D4 ne može se predvidjeti. Više vrijednosti HU povezane su sa višim vrednostima ISQ.

Opis (eng)

INTRODUCTION: Osseointegration stands as a prerequisite for the success of implant therapy. Bone quality and quantity, implant design, and surgical technique represent the most important factors influencing the primary stability of the implant, which is a prerequisite for osseointegration. METHODOLOGY: In order to solve the set objectives, an experimental study was conducted on a material of animal origin: bovine femur and pig ribs and a clinical prospective experimental study on humans, lacking one tooth in the lateral region indicated for implant placement. Two types of implants were used in this study: self-tapping (Bredent-Narrow SKY) and non selftapping (Nobel Replace - Conical Connection) of the same dimensions. RESULTS: Results of the experimental study showed a statistically significant correlation between bone density expressed in HU units and primary stability of self-tapping and non-selftapping dental implants expressed in ISQ units in bovine femur bones and self-tapping implants and pig rib bones. There was no statistically significant correlation between non-self-tapping dental implants in pig rib bones. Self-tapping and non-self tapping implants did not show statistical significance in primary stability in bones of different quality. In a clinical study, it was demonstrated that there is a statistically significant strong positive correlation between bone density expressed in HU units measured in CBCT apparatus software and primary stability of dental implants expressed in ISQ units; CONCLUSION: The analysis of bone density from CBCT images in the software of the apparatus expressed in HU units can be used to predict the degree of primary stability of self-tapping and non-self-tapping dental implants in bones of density D1, D2 and self-tapping dental implants in bones of lower quality D4. The degree of primary stability of non self-tapping dental implants in bones of lower quality D4 cannot be predicted. Higher HU values are associated with higher ISQ values.

Jezik

srpski

Datum

2020

Licenca

Creative Commons licenca
Ovo delo je licencirano pod uslovima licence
Creative Commons CC BY-NC-ND 2.0 AT - Creative Commons Autorstvo - Nekomercijalno - Bez prerada 2.0 Austria License.

CC BY-NC-ND 2.0 AT

http://creativecommons.org/licenses/by-nc-nd/2.0/at/

Identifikatori